Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
2.
J. bras. pneumol ; 45(5): e20180032, 2019. tab, graf
Article in English | LILACS | ID: biblio-1012574

ABSTRACT

ABSTRACT Objective: To investigate the accuracy of chest auscultation in detecting abnormal respiratory mechanics. Methods: We evaluated 200 mechanically ventilated patients in the immediate postoperative period after cardiac surgery. We assessed respiratory system mechanics - static compliance of the respiratory system (Cst,rs) and respiratory system resistance (R,rs) - after which two independent examiners, blinded to the respiratory system mechanics data, performed chest auscultation. Results: Neither decreased/abolished breath sounds nor crackles were associated with decreased Cst,rs (≤ 60 mL/cmH2O), regardless of the examiner. The overall accuracy of chest auscultation was 34.0% and 42.0% for examiners A and B, respectively. The sensitivity and specificity of chest auscultation for detecting decreased/abolished breath sounds or crackles were 25.1% and 68.3%, respectively, for examiner A, versus 36.4% and 63.4%, respectively, for examiner B. Based on the judgments made by examiner A, there was a weak association between increased R,rs (≥ 15 cmH2O/L/s) and rhonchi or wheezing (ϕ = 0.31, p < 0.01). The overall accuracy for detecting rhonchi or wheezing was 89.5% and 85.0% for examiners A and B, respectively. The sensitivity and specificity for detecting rhonchi or wheezing were 30.0% and 96.1%, respectively, for examiner A, versus 10.0% and 93.3%, respectively, for examiner B. Conclusions: Chest auscultation does not appear to be an accurate diagnostic method for detecting abnormal respiratory mechanics in mechanically ventilated patients in the immediate postoperative period after cardiac surgery.


RESUMO Objetivo: Investigar a acurácia da ausculta torácica na detecção de mecânica respiratória anormal. Métodos: Foram avaliados 200 pacientes sob ventilação mecânica no pós-operatório imediato de cirurgia cardíaca. Foi avaliada a mecânica do sistema respiratório - complacência estática do sistema respiratório (Cest,sr) e resistência do sistema respiratório (R,sr) - e, em seguida, dois examinadores independentes, que desconheciam os dados referentes à mecânica do sistema respiratório, realizaram a ausculta torácica. Resultados: Nem murmúrio vesicular diminuído/abolido nem crepitações foram associados à Cest,sr reduzida (≤ 60 ml/cmH2O), independentemente do examinador. A acurácia global da ausculta torácica foi de 34,0% e 42,0% para os examinadores A e B, respectivamente. A sensibilidade e a especificidade da ausculta torácica para a detecção de murmúrio vesicular diminuído/abolido e/ou crepitações foi de 25,1% e 68,3%, respectivamente, para o examinador A, versus 36,4% e 63,4%, respectivamente, para o examinador B. Com base nos julgamentos feitos pelo examinador A, houve uma fraca associação entre R,sr aumentada (≥ 15 cmH2O/l/s) e roncos e/ou sibilos (ϕ = 0,31, p < 0,01). A acurácia global para a detecção de roncos e/ou sibilos foi de 89,5% e 85,0% para os examinadores A e B, respectivamente. A sensibilidade e a especificidade para a detecção de roncos e/ou sibilos foi de 30,0% e 96,1%, respectivamente, para o examinador A, versus 10,0% e 93,3%, respectivamente, para o examinador B. Conclusões: A ausculta torácica não parece ser um método diagnóstico acurado para a detecção de mecânica respiratória anormal em pacientes sob ventilação mecânica no pós-operatório imediato de cirurgia cardíaca.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Respiration, Artificial/adverse effects , Respiration Disorders/diagnosis , Respiration Disorders/etiology , Auscultation/methods , Respiratory Mechanics , Cardiac Surgical Procedures/adverse effects , Reference Values , Respiration Disorders/physiopathology , Respiratory Function Tests , Observer Variation , Cross-Sectional Studies , Reproducibility of Results , Sensitivity and Specificity
4.
Barbas, Carmen Sílvia Valente; Ísola, Alexandre Marini; Farias, Augusto Manoel de Carvalho; Cavalcanti, Alexandre Biasi; Gama, Ana Maria Casati; Duarte, Antonio Carlos Magalhães; Vianna, Arthur; Serpa Neto, Ary; Bravim, Bruno de Arruda; Pinheiro, Bruno do Valle; Mazza, Bruno Franco; Carvalho, Carlos Roberto Ribeiro de; Toufen Júnior, Carlos; David, Cid Marcos Nascimento; Taniguchi, Corine; Mazza, Débora Dutra da Silveira; Dragosavac, Desanka; Toledo, Diogo Oliveira; Costa, Eduardo Leite; Caser, Eliana Bernadete; Silva, Eliezer; Amorim, Fabio Ferreira; Saddy, Felipe; Galas, Filomena Regina Barbosa Gomes; Silva, Gisele Sampaio; Matos, Gustavo Faissol Janot de; Emmerich, João Claudio; Valiatti, Jorge Luis dos Santos; Teles, José Mario Meira; Victorino, Josué Almeida; Ferreira, Juliana Carvalho; Prodomo, Luciana Passuello do Vale; Hajjar, Ludhmila Abrahão; Martins, Luiz Claudio; Malbouisson, Luis Marcelo Sá; Vargas, Mara Ambrosina de Oliveira; Reis, Marco Antonio Soares; Amato, Marcelo Brito Passos; Holanda, Marcelo Alcântara; Park, Marcelo; Jacomelli, Marcia; Tavares, Marcos; Damasceno, Marta Cristina Paulette; Assunção, Murillo Santucci César; Damasceno, Moyzes Pinto Coelho Duarte; Youssef, Nazah Cherif Mohamed; Teixeira, Paulo José Zimmermann; Caruso, Pedro; Duarte, Péricles Almeida Delfino; Messeder, Octavio; Eid, Raquel Caserta; Rodrigues, Ricardo Goulart; Jesus, Rodrigo Francisco de; Kairalla, Ronaldo Adib; Justino, Sandra; Nemer, Sergio Nogueira; Romero, Simone Barbosa; Amado, Verônica Moreira.
Rev. bras. ter. intensiva ; 26(3): 215-239, Jul-Sep/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-723283

ABSTRACT

O suporte ventilatório artificial invasivo e não invasivo ao paciente grave tem evoluído e inúmeras evidências têm surgido, podendo ter impacto na melhora da sobrevida e da qualidade do atendimento oferecido nas unidades de terapia intensiva no Brasil. Isto posto, a Associação de Medicina Intensiva Brasileira (AMIB) e a Sociedade Brasileira de Pneumologia e Tisiologia (SBPT) - representadas por seu Comitê de Ventilação Mecânica e sua Comissão de Terapia Intensiva, respectivamente, decidiram revisar a literatura e preparar recomendações sobre ventilação mecânica, objetivando oferecer aos associados um documento orientador das melhores práticas da ventilação mecânica na beira do leito, com base nas evidências existentes, sobre os 29 subtemas selecionados como mais relevantes no assunto. O projeto envolveu etapas que visaram distribuir os subtemas relevantes ao assunto entre experts indicados por ambas as sociedades, que tivessem publicações recentes no assunto e/ou atividades relevantes em ensino e pesquisa no Brasil, na área de ventilação mecânica. Esses profissionais, divididos por subtemas em duplas, responsabilizaram-se por fazer uma extensa revisão da literatura mundial. Reuniram-se todos no Fórum de Ventilação Mecânica, na sede da AMIB, na cidade de São Paulo (SP), em 3 e 4 de agosto de 2013, para finalização conjunta do texto de cada subtema e apresentação, apreciação, discussão e aprovação em plenária pelos 58 participantes, permitindo a elaboração de um documento final.


Perspectives on invasive and noninvasive ventilatory support for critically ill patients are evolving, as much evidence indicates that ventilation may have positive effects on patient survival and the quality of the care provided in intensive care units in Brazil. For those reasons, the Brazilian Association of Intensive Care Medicine (Associação de Medicina Intensiva Brasileira - AMIB) and the Brazilian Thoracic Society (Sociedade Brasileira de Pneumologia e Tisiologia - SBPT), represented by the Mechanical Ventilation Committee and the Commission of Intensive Therapy, respectively, decided to review the literature and draft recommendations for mechanical ventilation with the goal of creating a document for bedside guidance as to the best practices on mechanical ventilation available to their members. The document was based on the available evidence regarding 29 subtopics selected as the most relevant for the subject of interest. The project was developed in several stages, during which the selected topics were distributed among experts recommended by both societies with recent publications on the subject of interest and/or significant teaching and research activity in the field of mechanical ventilation in Brazil. The experts were divided into pairs that were charged with performing a thorough review of the international literature on each topic. All the experts met at the Forum on Mechanical Ventilation, which was held at the headquarters of AMIB in São Paulo on August 3 and 4, 2013, to collaboratively draft the final text corresponding to each sub-topic, which was presented to, appraised, discussed and approved in a plenary session that included all 58 participants and aimed to create the final document.


Subject(s)
Humans , Critical Care/methods , Practice Guidelines as Topic , Respiration, Artificial/methods , Brazil , Critical Care/standards , Critical Illness/therapy , Intensive Care Units/standards , Quality of Health Care
5.
Barbas, Carmen Sílvia Valente; Ísola, Alexandre Marini; Farias, Augusto Manoel de Carvalho; Cavalcanti, Alexandre Biasi; Gama, Ana Maria Casati; Duarte, Antonio Carlos Magalhães; Vianna, Arthur; Serpa Neto, Ary; Bravim, Bruno de Arruda; Pinheiro, Bruno do Valle; Mazza, Bruno Franco; Carvalho, Carlos Roberto Ribeiro de; Toufen Júnior, Carlos; David, Cid Marcos Nascimento; Taniguchi, Corine; Mazza, Débora Dutra da Silveira; Dragosavac, Desanka; Toledo, Diogo Oliveira; Costa, Eduardo Leite; Caser, Eliana Bernardete; Silva, Eliezer; Amorim, Fabio Ferreira; Saddy, Felipe; Galas, Filomena Regina Barbosa Gomes; Silva, Gisele Sampaio; Matos, Gustavo Faissol Janot de; Emmerich, João Claudio; Valiatti, Jorge Luis dos Santos; Teles, José Mario Meira; Victorino, Josué Almeida; Ferreira, Juliana Carvalho; Prodomo, Luciana Passuello do Vale; Hajjar, Ludhmila Abrahão; Martins, Luiz Cláudio; Malbouisson, Luiz Marcelo Sá; Vargas, Mara Ambrosina de Oliveira; Reis, Marco Antonio Soares; Amato, Marcelo Brito Passos; Holanda, Marcelo Alcântara; Park, Marcelo; Jacomelli, Marcia; Tavares, Marcos; Damasceno, Marta Cristina Paulette; Assunção, Murillo Santucci César; Damasceno, Moyzes Pinto Coelho Duarte; Youssef, Nazah Cherif Mohamad; Teixeira, Paulo José Zimmermann; Caruso, Pedro; Duarte, Péricles Almeida Delfino; Messeder, Octavio; Eid, Raquel Caserta; Rodrigues, Ricardo Goulart; Jesus, Rodrigo Francisco de; Kairalla, Ronaldo Adib; Justino, Sandra; Nemer, Sérgio Nogueira; Romero, Simone Barbosa; Amado, Verônica Moreira.
Rev. bras. ter. intensiva ; 26(2): 89-121, Apr-Jun/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-714821

ABSTRACT

O suporte ventilatório artificial invasivo e não invasivo ao paciente crítico tem evoluído e inúmeras evidências têm surgido, podendo ter impacto na melhora da sobrevida e da qualidade do atendimento oferecido nas unidades de terapia intensiva no Brasil. Isto posto, a Associação de Medicina Intensiva Brasileira (AMIB) e a Sociedade Brasileira de Pneumonia e Tisiologia (SBPT) - representadas pelo seus Comitê de Ventilação Mecânica e Comissão de Terapia Intensiva, respectivamente, decidiram revisar a literatura e preparar recomendações sobre ventilação mecânica objetivando oferecer aos associados um documento orientador das melhores práticas da ventilação mecânica na beira do leito, baseado nas evidencias existentes, sobre os 29 subtemas selecionados como mais relevantes no assunto. O projeto envolveu etapas visando distribuir os subtemas relevantes ao assunto entre experts indicados por ambas as sociedades que tivessem publicações recentes no assunto e/ou atividades relevantes em ensino e pesquisa no Brasil na área de ventilação mecânica. Esses profissionais, divididos por subtemas em duplas, responsabilizaram-se por fazer revisão extensa da literatura mundial sobre cada subtema. Reuniram-se todos no Forum de Ventilação Mecânica na sede da AMIB em São Paulo, em 03 e 04 de agosto de 2013 para finalização conjunta do texto de cada subtema e apresentação, apreciação, discussão e aprovação em plenária pelos 58 participantes, permitindo a elaboração de um documento final.


Perspectives on invasive and noninvasive ventilatory support for critically ill patients are evolving, as much evidence indicates that ventilation may have positive effects on patient survival and the quality of the care provided in intensive care units in Brazil. For those reasons, the Brazilian Association of Intensive Care Medicine (Associação de Medicina Intensiva Brasileira - AMIB) and the Brazilian Thoracic Society (Sociedade Brasileira de Pneumonia e Tisiologia - SBPT), represented by the Mechanical Ventilation Committee and the Commission of Intensive Therapy, respectively, decided to review the literature and draft recommendations for mechanical ventilation with the goal of creating a document for bedside guidance as to the best practices on mechanical ventilation available to their members. The document was based on the available evidence regarding 29 subtopics selected as the most relevant for the subject of interest. The project was developed in several stages, during which the selected topics were distributed among experts recommended by both societies with recent publications on the subject of interest and/or significant teaching and research activity in the field of mechanical ventilation in Brazil. The experts were divided into pairs that were charged with performing a thorough review of the international literature on each topic. All the experts met at the Forum on Mechanical Ventilation, which was held at the headquarters of AMIB in São Paulo on August 3 and 4, 2013, to collaboratively draft the final text corresponding to each sub-topic, which was presented to, appraised, discussed and approved in a plenary session that included all 58 participants and aimed to create the final document.


Subject(s)
Humans , Critical Illness/therapy , Practice Guidelines as Topic , Respiration, Artificial/methods , Brazil , Critical Care/methods , Intensive Care Units/standards , Quality of Health Care
6.
São Paulo; s.n; 2003. [125] p.
Thesis in Portuguese | LILACS | ID: lil-352297

ABSTRACT

O padrão ventilatório típico das doenças intersticiais pulmonares é o restritivo. Pode, entretanto, ocorrer obstrução ao fluxo aéreo, quando alterações inflamatórias e/ou fibrose envolvem as vias aéreas, na associação dessas doenças ao tabagismo e mais freqüentemente em doenças císticas e doenças granulomatosas. Em pacientes com doença pulmonar obstrutiva crônica (DPOC), a hiperinsuflação e a sobrecarga ventilatória decorrentes resultam em dispnéia durante o exercício. A redução de volumes após se usar broncodilatadores melhora a dispnéia e a capacidade para o exercício. OBJETIVO: Avaliar a resposta funcional ao broncodilatador (BD) das doenças intersticiais com padrão obstrutivo, sob repouso e sob exercício. MÉTODO: Estudo duplo cego, aleatório; cruzado, prospectivo, envolvendo 18 pacientes com doenças intersticiais difusas e relação entre volume expiratório forçado no primeiro segundo (VEF1) E capacidade vital forçada (VEF1/CVF) < 70 por cento. Os pacientes receberam aleatoriamente salbutamol 400g ou placebo. Realizou-se pletismografia, espirometria, ventilação voluntária máxima (VVM), capacidade de difusão do monóxido de carbono (DCO). Fez-se o teste de esforço máximo inicial e, em dia diferentes, os testes com carga constante (60 a 80 por cento da carga máxima atingida no teste de esforço máximo) com a curva fluxo-volume. Após período de repouso foram realizados os testes de caminhada de 6 minutos. Avaliou-se tempo de endurance, distância caminhada, dispnéia e fadiga muscular. RESULTADO Após se usar o BD houve melhora do VEF1 (placebo 1,76±0,55 e BD 1,96±0,61 p<0,001), CVF, resistência de vias aéreas (Rva), condutância específica de vias aéreas (Gva/V p) e VVM; não melhoram significativamente os volumes pulmonares estáticos. No exercício houve redução da capacidade inspiratória (CI). A redução da CI corelacuionou-se inversamente com a dispnéia (r=0,59, p<0,005). Durante o0 teste de exercício de carga constante a CI foi semelhante (1,670,43 L) após BD comparada ao placebo (1,62  0,51 L). Após BD a superposição entre a curva de volume corrente e o envelope máximo da curva fluxo-volume diminuiu, mas não melhoraram o tempo de endurance (10,9  6,5min...


Subject(s)
Bronchodilator Agents , Exercise , Lung Diseases, Interstitial
SELECTION OF CITATIONS
SEARCH DETAIL